Certifications And Standards; Technical Data; Product Safety Warnings - Assa Abloy NORTON RIXSON 6211 Installation Instructions Manual

Advertisement

NORTON
RIXSON
Contents

Certifications and Standards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Product Safety Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Template . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Certifications and Standards
ETL Certified: Operator conforms to ANSI/UL standard 325 for automatic closing doors and UL10C Positive
Pressure Fire Test for Door Assemblies.
ANSI A156.19: These products are designed to conform to this specification "for power assist and low energy
power operated doors." These products are designed to exceed all the requirements for "Low Energy Power
Operated Door".
Americans with Disabilities Act (A.D.A.): These door operators can be installed and adjusted to conform with
A.D.A. regulations.
ANSI A117.1: These door controls permit door assemblies to conform to the requirements of this specification "for
buildings and facilities - providing accessibility and usability for physically handicap people".
Technical Data
Input power:
Power supply:
Door width:
Door weight:
Push max angle:
Pull max angle:
Hold open time:
Product Safety Warnings
WARNING: To reduce risk of injury to person, use this operator only with Pedestrian Swing doors. FOR INDOOR USE ONLY
1.
READ AND FOLLOW ALL INSTRUCTIONS.
2.
Install only on a properly operating and balanced door.
A door that is operating improperly could cause severe
injury. Have qualified service personnel make repairs to
any hardware before installing the operator.
3.
Remove, or make inoperative, all locks (unless
mechanically and/or electrically interlocked to the power
unit) that are connected to the door before installing the
operator.
4.
Do not connect the door operator to the source power
until instructed to do so.
5.
Never let children operate or play with door controls. Keep
remote control (when provided) away from children.
2
120VAC, 60Hz 3.0A
24 V DC, max. 4.5 Amp. ; .4A Available for Acc.
36 - 48" (91-122 cm)
90-200 lb. (41-91 kg)
130° with reveal of 1/8" to 3-1/4" (3 to 82.5 mm)
120°
5-30 seconds (A.D.A. 5 seconds min.)
Indefinite for Hold Open Input or End Cap 3
Position Switch
Copyright © 2022, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or in
part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
Approved 2022-06-13
6211 Series (PULL Side) Power Operator
NOTE:
Permanent wiring is to be employed as required by
local codes.
Activation devices: push plates, access control, mats,
touchless wall switches, etc.
Maximum wire size is:
6.
Personnel should keep away from a moving door in
motion.
7.
Test door's safety features at least once a month.
After adjusting either force or limit of travel, retest
door operator's safety features. Failure to adjust
operator properly may cause severe injury or death.
8.
KEEP DOOR PROPERLY OPERATING. See Door
Manufacturer's Owner's Manual. An improperly
operating door could cause severe injury or death.
Have a trained door systems technician make
repairs.
9.
SAVE THESE INSTRUCTIONS.
12AWG at terminals LINE and NEUTRAL
(120VAC; 60Hz) on Power Input Terminal
14AWG at all other terminals
80-9363-0023-020 Rev 1 03/22