6.2.16
Function of locks
The control unit has an available output of DC for external locks
The lock output is short circuit proof and can supply a lock with 12 V DC, max. 1200 mA or 24
V DC, max. 600 mA. Lock function is active in mode "Off / Closed" and "Exit".
Select 12 V DC or 24 V DC, locked with or without power
Lock release and opening delay
If the door cannot fully close, the operator will perform a lock retry (once if manually, twice if
automatically open).
6.2.17
Impulses
Input for INNER / OUTER / KEY impulse.
6.2.18
Statistics
Record data of the action for the door.
6.2.19
Factory reset
Will restore all settings with factory default settings.
All users that have previously been connected to the door will be removed. Owner need to re-
take ownership and re-add all users.
1022077-en-4.0
Issue 2023-01-17
6 How the ASSA ABLOY SW60 works
15