Total power rating
See data plate
Connection data
The connection data is quoted on the
data plate. Please ensure these match
the household mains supply.
Please see wiring diagrams for connec-
tion. (N.B. This appliance is supplied
single phase only in the UK / AUS / NZ).
Replacing the mains connection cable
Risk of electric shock.
Incorrect connection to the power
supply may result in an electric
shock.
The mains cable must only be re-
placed by a qualified electrician.
When replacing the mains cable only
use cable type H 05 VV-F (PVC insu-
lated) with a suitable cross section. A
suitable connection cable is available to
order from Miele.
Disconnecting from the mains
Risk of electric shock from mains
voltage.
There is a risk of electric shock if the
appliance is reconnected to the
mains voltage supply during repair or
service work.
After disconnection, ensure the appli-
ance cannot be switched back on by
mistake.
To disconnect the combination steam
oven from the mains power supply, do
one of the following depending on in-
stallation:
Safety fuses
Completely remove the fuse links
from the screw caps.
Automatic circuit breakers
Press the test button (red) until the
middle button (black) springs out.
Built-in circuit breakers
For circuit breakers of at least type B
or C, switch the lever from 1 (on) to 0
(off).
Residual current device
Residual current device: switch the
main switch from 1 (on) to 0 (off) or
press the test button.
Wiring diagram
WARNING
THIS APPLIANCE MUST BE
EARTHED
Installation
173