D6001DE-L Series Double Egress Power Operator Unit
C. Install Conduit Assembly and wire to building.
1. Orient conduit assembly so two (2) conduit holes
are at bottom and text on wire input label is
legible. (Figure 13)
2. Secure assembly to backplate using four (4) #8-
32 x 5/16" Phillips head screws. (Figure 13)
WARNING: BUILDING POWER MUST BE OFF
BEFORE PROCEEDING!
3. Secure conduits to conduit assembly (surface or
concealed conduit). (Figure 14)
4. Wire building 120VAC to conduit assembly –
LINE, NEUTRAL, and GROUND. (See General
Electrical Information on page 14.)
5. Wire 24VDC for accessories to conduit assembly
24VDC + / - as required. (See General Electrical
Information on page 14.)
WARNING: DO NOT TURN ON BUILDING
POWER UNTIL DIRECTED TO DO SO! RISK
OF INJURY OR DEATH!
D. Install Power Module Sub-assemblies.
1. Using three (3) #8-32 x 5/16" Phillips screws per
assembly, secure power module sub-assemblies
to backplate at location marked on backplates.
(Figure 15)
NOTE: Orient assemblies so LCD screens on
inverters are toward corresponding closer
assemblies. (Figure 15)
Closer
Copyright © 2023, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or in part
without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9360-1048-020 Rev 1 01/23
LCD Screen
Power Module Sub-assembly
Mounting Screws
Approved 2023-11-10
Left Door LAP
Wire Input
Labels
Figure 13
Figure 14
Power Module Sub-assembly
Mounting Screws
LCD Screen
Wiring Removed From View
Figure 15
Conduit Assembly
Mounting Screws
Right Door LAP
Conduit Holes
Closer