Finalize Installation; General Electrical Information - Assa Abloy Norton 6011 Series Installation Instructions Manual

Pull side power operator
Hide thumbs Also See for Norton 6011 Series:
Table of Contents

Advertisement

6011/6051 Series (Pull Side) Power Operator
Attach Cover to finalize installation
1.
Align cut-outs in cover to pinion shafts.
(Figure 29)
2.
Slide cover onto unit using end cap and union
spacer as guides.
NOTE: Verify all wiring and sheet metal
guards are inside cover.
3.
Snap cover securely to backplate. Pull on
cover to verify it is secure.
NOTE: If cover will not securely snap onto
backplate, verify backplate is not warped or
twisted. Additional support or shimming may
be required. See Sections A & B under Prepare
Frame and Door.
Power inputs at power input connection and
power output contacts must be made with
copper wire only.
Maximum wire size:
12 AWG at power input connection
14 AWG at all other terminals.
Power input at terminals LINE and NEUTRAL
must be 120VAC at 60 Hz (+10%, -15%).
Maximum current draw from auxiliary
devices is 1.3 amps.
All wiring and connections use standard
wiring practice conforming with local wiring
codes.
Labeled fire or smoke barrier door
assemblies require 120VAC 60Hz power
input be supplied through normally closed
alarm contacts of the alarm system / alarm
panel.
Copyright © 2019, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9360-1026-020 Rev 4 11/19
Figure 29
WARNING: Make sure no wiring is loose or can be
caught by cover when it is snapped into place.

General Electrical Information

Pinion Shaft Cut-out
13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents