Maintenance
Maintenance
Dust collection filter
Replace about every 10 years
About part replacement timing
• Replacement timing depends on usage patterns and the
location of the unit.
Standard replacement time is about 10 years assuming
that the unit is used daily in a home where 5 cigarettes
are smoked a day. (Calculation in accordance with testing
method of Japan Electrical Manufacturers' Association
JEM1467 standard)
If the impurity content of the ambient air is high, the filter
will need more frequent replacement.
If the filter is failing to perform, it is time to replace it.
1.
Remove the water tank.
2.
Remove the humidifying tray.
3.
Remove the filter fixing unit.
4.
Remove the deodorising filter.
Hold the side of the filter and remove it.
5.
Remove the dust collection filter.
1 Pull the filter tag upward.
2 Hold the lower part of the dust collection filter and
lift it out.
43
Attention
Be sure to operate with the dust collection filter and deodorising filter attached.
If the unit is operated without the filters attached, malfunction may result.
Replace
►Page 17
►Page 15
►Page 15
Deodorising filter
Dust collection filter
About purchasing and disposal
¼ Refer to "Separately Sold Parts".
6.
Attach a new dust collection filter.
• If it is hard to install, push the dust collection filter
while installing.
7.
Attach the deodorising filter.
8.
Attach the filter fixing unit.
9.
Attach the humidifying tray.
10.
Put the water tank in.