Check Item
Alarm information
Function
Running data
Appearance
----End
Issue 02 (2023-02-28)
Copyright © Huawei Digital Power Technologies Co., Ltd.
Criteria
No major or minor component alarms are generated.
The communication and charging/discharging
functions are normal.
● Number of modules: 12
● Module voltage range: 43.2–58 V
● Cell voltage range: 2.5–3.65 V
● Module temperature range: –20°C to +55°C
● There is no obvious damage to the appearance.
● There is no obvious paint peeling or rust.
● The screws are secured.
● The fans rotate properly without abnormal sound.
● The front panel vent is clean and free from
blockage.