6. Now that parameter 201 has been changed back to dash (-), we are ready to re-assign a gas
train type. With parameter 201 still displayed, press "Enter". Toggle the "+" button to
reassign the value to 1. Submit this value to the control by pressing "Enter" again. For
direct ignition gas burners, the gas train type is 1.
7. Press "Esc" ("+" and "-" simultaneously) to exit the "200: Set" parameters.
8. Toggle the "+" arrow to settle on "400: Set". Press "Enter"
9. Here parameter 201 should appear again, with the pre-set value of 1 to the right of the
display.
10. Proceed through the setup by clicking "+".
11. Parameter 542 will appear with a value of 0 displayed on the right. This parameter is to set
the VSD fan. If no VSD fan is used, it remains at 0. However, if a VSD fan is used, press
"Enter". Toggle the "+" arrow and change the value to 1. Press "Enter" to submit
whichever value desired.
12. To move to the next parameter, click "+". Parameter 641 will appear. If your value for
parameter 542 was 0, 642 will be the same. If parameter 542 was changed to 1, parameter
641 will also change to 1. Parameter 641 controls the speed standardization of the VSD.
13. Click "+" to proceed to the next parameter.
14. On this screen, P0 appears flashing. P0 is your ignition setpoint.
63899-002 Rev. A 3/20/2024