Alarms/Event Log Parameters - Danfoss ICM User Manual

Motorized valves with actuators
Table of Contents

Advertisement

ICM and ICMTS Motorized Valves with ICAD Actuators
Parameter
Description and selection
Label ID
name
options
Timestamp of the alarm oc-
A18
currence relative to the run-
timestamp
time counter (ID48),
ID140
(Warn: Vin
Or -1 (0xFFFFFFFF in hex) if
>24+10%)
the alarm is not set
Timestamp of the alarm oc-
A19
currence relative to the run-
timestamp
time counter (ID48),
ID141
(Warn: Vin
Or -1 (0xFFFFFFFF in hex) if
<24-15%)
the alarm is not set
Timestamp of the alarm oc-
A20
currence relative to the run-
timestamp
time counter (ID48),
ID146
(Alarm: De-
Or -1 (0xFFFFFFFF in hex) if
tection fail)
the alarm is not set
A2(3)
Timestamp of the alarm oc-
timestamp
currence relative to the run-
(Alarm: EE-
time counter (ID48),
ID148
PROM opera-
Or -1 (0xFFFFFFFF in hex) if
tion fail)
the alarm is not set
A2(4)
Timestamp of the alarm oc-
timestamp
currence relative to the run-
(Alarm: Blue-
time counter (ID48),
ID149
tooth MCU
Or -1 (0xFFFFFFFF in hex) if
comm fail)
the alarm is not set
A3(5)
Timestamp of the alarm oc-
timestamp
currence relative to the run-
(Alarm: Mod-
time counter (ID48),
ID150
bus connec-
Or -1 (0xFFFFFFFF in hex) if
tion lost)
the alarm is not set
A1(2)
Timestamp of the alarm oc-
timestamp
currence relative to the run-
(Warn: Input
time counter (ID48),
ID152
signal not
Or -1 (0xFFFFFFFF in hex) if
the alarm is not set
con gured)

Alarms/Event Log Parameters

Parameter
Description and selection
Label ID
name
options
Readout the total stalls
(times ICAD stopped due to
A9 alarms) done by the ICAD
Stalls
ID43
from when it was rst pow-
ered on or factory reset.
Saved every 30min
Readout the total strokes
(movement) done by the
ICAD from when it was rst
powered on or factory reset.
Full strokes
ID46
Saved every 30min.
Full strokes are de ned as
0% to 100% to 0% opening
degree.
Alarm
Total number of A9 alarms
ID230
A9 (total
for the ICAD is tracked.
counter)
© Danfoss | Climate Solutions | 2024.01
Factory set‐
Min.
Max.
ting
4294967295
(-1,
-1
4294967294
or
0xFFFFFFFF
in hex)
4294967295
(-1,
-1
4294967294
or
0xFFFFFFFF
in hex)
4294967295
(-1,
-1
4294967294
or
0xFFFFFFFF
in hex)
4294967295
(-1,
-1
4294967294
or
0xFFFFFFFF
in hex)
4294967295
(-1,
-1
4294967294
or
0xFFFFFFFF
in hex)
4294967295
(-1,
-1
4294967294
or
0xFFFFFFFF
in hex)
4294967295
(-1,
-1
4294967294
or
0xFFFFFFFF
in hex)
Factory set‐
Min.
Max.
ting
0
32764
0
0
4294967293
0
0
32764
0
Pass‐
Alterna‐
word
Modbus
tive
Size in
level to
address
Modbus
bytes
Read -
address
Write
3240 ...
3444 ...
4
1
3241
3445
3242 ...
3446 ...
4
1
3243
3447
3244 ...
3448 ...
4
1
3245
3449
3246 ...
3450 ...
4
1
3247
3451
3248 ...
3452 ...
4
1
3249
3453
3250 ...
3454 ...
4
1
3251
3455
3252 ...
3456 ...
4
1
3253
3457
Pass‐
Alterna‐
word
Modbus
tive
Size in
level to
address
Modbus
bytes
Read -
address
Write
3120
3396
2
1
3121 ...
3397 ...
4
1
3122
3398
3124
3399
2
1
BC465027827472en-000102 | 33
Read
only
(RO) /
Persis‐
Modbus
Read
tent
func‐
Write
Yes/No
tion
(RW) /
Write
(W)
RO
No
3
RO
No
3
RO
No
3
RO
No
3
RO
No
3
RO
No
3
RO
No
3
Read
only
(RO) /
Persis‐
Modbus
Read
tent
func‐
Write
Yes/No
tion
(RW) /
Write
(W)
RO
Yes
3
RO
Yes
3
RO
Yes
3