The Acs-8910 Configuration Menu; Quick Setup Menu - Accusys ACS-8910 User Manual

Table of Contents

Advertisement

4.3 The ACS-8910 Configuration Menu

The ACS-8910 should be disconnected from the host system when running the Configuration Menu.
The Main Menu consists of 6 categories. Each category is used to configure a different part of the
ACS-8910 controller. The following shows the main menu categories. Each category has sub-menu
and options. In the following sections, each main hierarchy will be described in details.

4.3.1 Quick Setup menu

The Quick Setup menu, which provides a quickly RAID level 5 configuration. On the other hand,
all the installed disks will be configured to RAID level 5.
Sub-menu
01 Quick Setup
Description:
Sub-menu
011 Reconfim
Description:
Main Menu
0 Quick Setup
1 RAID Params
2 SCSI Params
3 RS232 Params
4 System Params
5 NVRAM
6 RAID Func
7 Special
Settings
No, Yes
This procedure will provide a quickly way to setup a RAID
5 configuration.
NOTE 1:
You will change to new setup if RAID old
configuration has exited.
NOTE 2: The original data will be lost if you execute
this quick setup.
Settings
No, Yes
Re-confirm Quick Setup procedures.
NOTE: The RAID controller will re-start automatically
after pressing "Yes" from Re-confirm menu
Default setting
No
Default setting
No