Automatic Drive Rebuild - Accusys ACS-8910 User Manual

Table of Contents

Advertisement

2.2.3 Automatic Drive Rebuild

When one of the drive fails, the controller will check if there is any local spare drive assigned to this
logical drive first; If yes, the controller will start to rebuild lost data atomatically.
If not, the controller will search for a Global Spare Drive; if the Global Spare Drive is available, the
controller will auto-rebuild lost data.
If neither Local Spare Drive nor Global Spare Drive is available, the controller will not try to rebuild
unless the user applies a forced-manual rebuild.
Automatic Rebuild
One member drive
fails in logical drive
Any Global
Spare Drive
assigned to
this logical
No
Wait for new drive to
automatic rebuild
Automatic
Yes
Rebuild using
the Global
Spare Drive
13