33.2.10 speed-duplex

Syntax:
speed-duplex <auto|10-half|10-full|100-half|100-full|1000-full>
where
<auto|10-half|10-
full|100-half|100-
full|1000-full>
An example is shown next.
• Enable ports one, three, four and five for configuration.
• Set the speed to 100 Mbps in half duplex mode.
sysname(config)# interface port-channel 1,3-5
sysname(config-interface)# speed-duplex 100-half

33.2.11 test

You can perform an interface loopback test on specified ports. The test returns
Failed!
An example is shown next.
• Select ports 3-6 for internal loopback test.
• Execute the test command.
• View the results.
sysname(config)# interface port-channel 3-6
sysname(config-interface)# test 3-6
Testing internal loopback on port 3 :Passed!
Ethernet Port 3 Test ok.
Testing internal loopback on port 4 :Passed!
Ethernet Port 4 Test ok.
Testing internal loopback on port 5 :Passed!
Ethernet Port 5 Test ok.
Testing internal loopback on port 6 :Passed!
Ethernet Port 6 Test ok.
236
=
Sets the duplex mode (half or full) and speed (10, 100 or 1000
Mbps) of the connection on the port. Selecting auto (auto-
negotiation) makes one port able to negotiate with a peer
automatically to obtain the connection speed and duplex mode
that both ends support.