2.2 Mounting the Switch on a Rack

This section lists the rack mounting requirements and precautions and describes the
installation steps.

2.2.1 Rack-mounted Installation Requirements

• Two mounting brackets.
• Eight M3 flat head screws and a #2 Philips screwdriver.
• Four M5 flat head screws and a #2 Philips screwdriver.
Note: Failure to use the proper screws may damage the unit.

2.2.1.1 Precautions

• Make sure the rack will safely support the combined weight of all the equipment it
contains.
• Make sure the position of the switch does not make the rack unstable or top-heavy. Take
all necessary precautions to anchor the rack securely before installing the unit.

2.2.2 Attaching the Mounting Brackets to the Switch

1 Position a mounting bracket on one side of the switch, lining up the four screw holes on
the bracket with the screw holes on the side of the switch.

Figure 7 Attaching the Mounting Brackets

2 Using a #2 Philips screwdriver, install the M3 flat head screws through the mounting
bracket holes into the switch.
3 Repeat steps
switch.
4 You may now mount the switch on a rack. Proceed to the next section.
2.2.3 Mounting the Switch on a Rack
1 Position a mounting bracket (that is already attached to the switch) on one side of the
rack, lining up the two screw holes on the bracket with the screw holes on the side of the
rack.
40
1
and
2
to install the second mounting bracket on the other side of the
Chapter 2 Hardware Installation and Connection