4.2

GROUND CONTROL OPERATION

4.2.1
GROUND CONTROL FUNCTIONS
1 Emergency Stop
2 Green Power Button
3 Red Lamp
4 Red Lamp
5 Green Lamp
6 Engine Glow & Start/Stop
7 Base/Platform Selector
8 Transport Selector
9 Auxiliary Powered Descent
English/USA – 04/15
Original instructions
Operating & Safety Instructions
Push to Stop Operation
Push and hold for Power
Indicates Safe Working Load limit or Maximum Tilt Angle
exceeded. Safely remove any unnecessary items from the
platform or lower booms to stowed position and drive on to level
ground to restore machine functions.
Indicates maximum Cage Level Angle exceeded.
Press Aux Powered Descent button (9) whilst operating the
platform levelling lever to relevel the cage in order to restore cage
functions.
Indicates machine is switched on. Lamp will extinguish during a
safety critical condition when red lamp (3 or 4) is flashing.
Anti-clockwise for Glow, Clockwise to Start/Stop engine
Clockwise for Platform, Centre for Base, 0 for all power off
Turn Clockwise to allow cage to be 'tucked in' for transportation
purposes.
Push and hold to enable boom functions in the event of normal
operation loss. (i.e. Fuel tank empty)
Height Rider/SP Series
Twist to Enable Operation
Release to Cease operation
23