Emergency Controls; General; In The Event Of An Incapacitated Operator; In The Event Of Machine Failure - nifty Heightrider HR28 Series Operating/Safety Instructions Manual

Table of Contents

Advertisement

Height Rider/SP Series
Operating & Safety Instructions
5

Emergency Controls

5.1

GENERAL

CHECKING THE OPERATION OF THE EMERGENCY CONTROLS EVERY DAY
AND/OR BEFORE EACH SHIFT IS AN ESSENTIAL PART OF THE OPERATOR'S
DUTIES
The operator and all ground personnel must be thoroughly familiar with the location and operation of
the emergency controls.
5.2

IN THE EVENT OF AN INCAPACITATED OPERATOR

Turn the key switch at the ground control station to ground (central position).
Manoeuvre the machine using the ground controls as described previously in Section 4.2.
5.3

IN THE EVENT OF MACHINE FAILURE

If all machine power is lost, the auxiliary emergency pump can be used to provide the hydraulic
power to manoeuvre the machine (Refer to Section 4.2.2). If initial movement of the machine allows
the master alarm to reset, normal controls will be available. This is then the fastest method of lowering
the platform to the ground.
Note: If the machine is fitted with a cage overload system, and the cage comes into contact with a
fixed object whilst operating at height, this would be detected as an overload condition. All power to
the machine controls would be lost, requiring the machine to be recovered using the auxiliary
emergency pump. It is sufficient for the cage to be manoeuvred away from the collision point to re-
set the cage weigh mechanism, thereby restoring normal machine operation. The cage can now be
lowered using the controls as described previously in Section 4.3.
FOLLOWING AN EMERGENCY DESCENT RECOVERY OF THE PLATFORM, FULLY
EXTEND AND RETRACT ALL CYLINDERS FROM GROUND CONTROL STATION
BEFORE USING THE MACHINE.
5.4

INCIDENT NOTIFICATION

It is a mandatory requirement that any accident or incident involving a Niftylift, regardless of whether
any party received injury or property was damaged is reported by telephone directly to Niftylift. Failure
to do so may render any warranty on the machine void.