nifty Heightrider HR28 Series Operating/Safety Instructions Manual page 28

Table of Contents

Advertisement

Height Rider/SP Series
Operating & Safety Instructions
EMERGENCY PROCEDURES
1)
Push in red emergency stop to shut down all functions.
2)
In the event that the controls fail or the operator becomes incapacitated the booms can be
operated by using the auxiliary emergency pump which is located under the canopy adjacent
to the base controls as follows:
a)
Operate appropriate control lever as required.
b)
Press and hold the white button adjacent to the base controls. (Refer to Section 4.2.1)
Note: if lowering the telescopic boom, it will be necessary to also operate the manual
levelling lever (Refer to Section 4.2.1) to ensure the platform remains level. It is
recommended to halt boom lowering, level platform then commence with descent.
Repeat this in stages as the boom is lowered.
c)
Release white button to halt machine movement.
d)
Release control lever.
26
English/USA – 04/15
Original instructions