55
Freeze Protection
If the temperature sensors within the heater detect a low enough temperature, then the pump will automatically activate to
provide freeze protection. The pump will run either continuously or periodically depending on conditions.
Clean-up Cycle
When a pump is turned on by a button press, a clean-up cycle begins 30 minutes after the pump is turned off or times out. The
pump and the ozone generator will run for 30 minutes or more, depending on the system.
Temperature and Temp
Adjusting the Set Temperature
The panel has Up and Down buttons (Temperature buttons), pressing Up or Down will cause the temperature to flash. Pressing
a temperature button again will adjust the set temperature in the direction indicated on the button. When the LCD stops flashing,
the spa will heat to the new set temperature when required. Spa temperature can be set between 50°F and 104°F.
Press-and-Hold
If a Temperature button is pressed and held when the temperature is flashing, the temperature will continue to change until the
button is released.
NOTE: Spa will not reach set temp if unit is in Low Range. Check settings to be sure unit is in High Range to reach temps above
99°F.
Dual Temperature Ranges
This system incorporates two temperature range settings with independent set temperatures. The High Range designated in the
display by an "up" arrow, and the Low Range designated in the display by a "down" arrow.
These ranges can be used for various reasons, with a common use being a "ready to use" setting vs. a "vacation" setting. The
Ranges are chosen using the menu structure below. Each range maintains its own set temperature as programmed by the user.
This way, when a range is chosen, the spa will heat to the set temperature associated with that range. For example: High range
might be set between 80°F and 104°F. Low range might be set between 50°F and 99°F. Freeze protection is active in either range.
1) Press menu key TEMP will be displayed.
2) Use Up or Down arrow to change from High to Low range. A small Up arrow or Down arrow icon will be displayed on the
screen.
NOTE: Spa will not reach set temp if unit is in Low Range. Check settings to be sure unit is in High Range to reach temps above
99°F.
Mode, Ready and Rest
In order for the spa to heat, a pump needs to circulate water through the heater. The pump that performs this function is known as
the "heater pump."
READY Mode will circulate water periodically, using Pump 1 Low, in order to maintain a constant water temperature, heat as need-
ed, and refresh the temperature display. This is known as "polling."
REST Mode will only allow heating during programmed filter cycles. Since polling does not occur, the temperature display may not
show a current temperature until the pump has been running for a minute or two.
Ready-in-Rest Mode
READY/REST appears in the display if the spa is in Rest Mode and Jet 1 is pressed. It is assumed that the spa is being used and
will heat to set temperature. While pump High can be turned on and off, pump Low will run until set temperature is reached, or
1 hour has passed. After 1 hour, the System will revert to Rest Mode. This mode can also be reset by entering the Mode Menu and
changing the Mode.