Operation Systems, Luxury Series | SmartTouch™ Control
43
General
Most messages and alerts will appear at the bottom of the normally used screens. Several alerts and messages may be displayed in
a sequence.
Water Temperature is Unknown
After the pump has been running for 1 minute, the temperature will be displayed
– – – –
– – – –
°F
°C
Possible Freezing Condition
A potential freeze condition has been detected. All water devices are activated. In some cases,
pumps may turn on and off and the heater may operate during Freeze Protection. This is an
operational message, not an error indication.
The Water is Too Hot—M029*
The system has detected a spa water temp of 110°F (43.3°C) or more, and spa functions are disabled. System will auto reset when
the spa water temp is below 108°F (42.2°C). Check for extended pump operation or high ambient temp.
Heater Related
The Water Flow is Low—M016*
There may not be enough water flow through the heater to carry the heat away from the heating element. Heater start up will
begin again after about 1 min. See "Flow Related Checks" below.
The Water Flow had Failed* - M017*
There is not enough water flow through the heater to carry the heat away from the heating element and the heater has been
disabled. See "Flow Related Checks" below. After the problem has been resolved, reset the message*.
The Heater may be Dry* - M028**
Possible dry heater, or not enough water in the heater to start it. The spa is shut down for 15 min. Reset this message* to reset the
heater start-up. See "Flow Related Checks" below.
The Heater is Dry* - M027**
There is not enough water in the heater to start it. The spa is shut down. After the problem has
been resolved, you must reset the message* to restart heater start up. See "Flow Related
Checks" below.
The Heater is Too Hot* - M030**
One of the water temp sensors has detected 118°f (47.8°C) in the heater and the spa is shut
down. You must reset the message* when water is below 108°f (42.2°C).
Flow-Related Checks
Check for low water level, suction flow restrictions, closed valves, trapped air, too many closed jets and pump prime.
On some systems, even when spa is shut down by an error condition, some equipment may occasionally turn on to continue
monitoring temperature or if freeze protection is needed.
* Some messages can be reset from the panel. Messages that can be reset will appear
with a Clear Icon at the bottom of the Message Screen. Press the Clear Icon text to reset
the message.