Selecting the Wordclock Source
Note: When the wordclock source is changed on the wordclock master device, noise may
occur from the SREV1's outputs, especially if an MY8-AT I/O card is installed, so turn
down your power amps beforehand, otherwise any connected speakers may be damaged.
Use the [UTILITY] button to locate the DIO page shown below.
1
Use the cursor buttons to select a source.
2
The button for the currently selected source appears highlighted.
The following wordclock sources can be selected.
Condition
Always available
When lockable
external wordclock
present
AES/EBU I/O card
installed (MY8-AE)
& lockable
wordclock present
ADAT or Tascam I/O
card installed
(MY8-AT, MY8-TD)
& lockable
wordclock present
This button indicates that a wordclock signal is present and that it's at the
same frequency as the currently selected source. This source can be selected.
This button indicates that although a wordclock signal is present, it's not at
the same frequency as the currently selected source. This source can be
selected.
This button indicates that no wordclock signal is present. This source cannot
be selected.
The button of the selected source appears highlighted, as shown here.
Selecting the Wordclock Source
Source
Description
INT 48K
Internal 48 kHz wordclock (default setting)
WCLK IN
External wordclock via the BNC WORD CLOCK IN
AES/EBU1
External wordclock via the AES/EBU IN 1
AES/EBU2
External wordclock via the AES/EBU IN 2
SLOT x 1/2
External wordclock via slot x, input pair 1/2
SLOT x 3/4
External wordclock via slot x, input pair 3/4
SLOT x 5/6
External wordclock via slot x, input pair 5/6
SLOT x 7/8
External wordclock via slot x, input pair 7/8
SLOT x
External wordclock via slot x
75
SREV1—Owner's Manual