9.2 Troubleshooting and Routine Maintenance

Troubleshooting
a.
Please check the fault message on the System Control Panel or the fault code on the inverter
information panel. If a message is displayed, record it before doing anything further.
b.
Attempt the solution indicated in table above.
c.
If your inverter information panel is not displaying a fault light, check the following to make sure that
the current state of the installation allows for proper operation of the unit:
(1)
Is the inverter located in a clean, dry, adequately ventilated place?
(2)
Have the DC input breakers opened?
(3)
Are the cables adequately sized?
(4)
Are the input and output connections and wiring in good condition?
(5)
Are the configurations settings correct for your particular installation?
(6)
Are the display panel and the communications cable properly connected and undamaged?
Contact Energizer Solar Customer Service for further assistance. Please be prepared to describe details
of your system installation and provide the model and serial number of the unit.
Safety check
A safety check should be performed at least every 12 months by a qualified technician who has adequate
training, knowledge and practical experience to perform these tests. The data should be recorded in an
equipment log. If the device is not functioning properly or fails any of the tests, the device has to be
repaired. For safety check details, refer to section 2 of this manual.
Maintenance checking list
During the process of using the inverter, the responsible person shall examine and maintain the machine
regularly. The required actions are as follows.
-
Check that if the cooling fins at the rear of the inverters are collecting dust/dirt, and the machine
should be cleaned when necessary. This work should be conducted periodically.
-
Check that if the indicators of the inverter are in normal state, check if the display of the inverter is
normal. These checks should be performed at least every 6 months.
-
Check if the input and output wires are damaged or aged. This check should be performed at least
every 6 months.
-
Get the inverter panels cleaned and their security checked at least every 6 months.
Note: Only qualified individuals may perform the following works.
The cell manufacture is different.
• Please contact battery supplier.
The slave software and hardware are not match.
• Please contact battery supplier.
The software between Master and Slave are not match.
• Please contact battery supplier.
No action for charging request.
• Please contact battery supplier.