M1 Close Fault
M2 Close Fault
GridV Cons Fault
GridF Cons Fault
Dci Cons Fault
Rc Cons Fault
RDSP SPI Fault
RDSP Smpl Fault
ARM EEPROM Fault
Meter Lost Fault
BMS Lost
Bms Ext Fault
Bms Int Fault
The grid relay M1 keep close.
• Disconnect PV, grid and battery, then reconnect.
• Or seek help from us, if not go back to normal state.
The grid relay M2 keep close.
• Disconnect PV, grid and battery, then reconnect.
• Or seek help from us, if not go back to normal state.
The grid voltage sample value between master and slave is not consistent.
• Disconnect PV, grid and battery, then reconnect.
• Or seek help from us, if not go back to normal state.
The grid frequency sample value between master and slave is not consistent.
• Disconnect PV, grid and battery, then reconnect.
• Or seek help from us, if not go back to normal state.
The dci sample value between master and slave is not consistent.
• Disconnect PV, grid and battery, then reconnect.
• Or seek help from us, if not go back to normal state.
The residual current sample value between master and slave is not consistent.
• Disconnect PV, grid and battery, then reconnect.
• Or seek help from us, if not go back to normal state.
The communication between master and slave is fail.
• Disconnect PV, grid and battery, then reconnect.
• Or seek help from us, if not go back to normal state.
The slave sample detection circuit is failed.
• Disconnect PV, grid and battery, then reconnect.
• Or seek help from us, if not go back to normal state.
The manager eeprom is fault.
• Disconnect PV, grid and battery, then reconnect.
• Or seek help from us, if not go back to normal state.
The communication between meter and Inverter is interrupted.
• Check if the communication cable between meter and Inverter is correctly and
well connected.
The communication between BMS and Inverter is interrupted.
• Check if the communication cable between BMS and Inverter is correctly and
well connected.
The communication between BMS and Inverter is interrupted.
• Check if the communication cable between BMS and Inverter is correctly and
well connected.
DIP switch at the wrong position;
The communication between battery packs is interrupted.
• Move the DIP switch to the correct position;
• Check if the communication cable between battery packs is correctly and well
connected.