Separate the DC connector (battery) as below.
Plug
Insert striped cable into pin contact and ensure all conductor strands are captured in the pin contact.
Crimp pin contact by using a crimping plier. Put the pin contact with striped cable into the
corresponding crimping pliers and crimp the contact.
Insert pin contact through the cable nut to assemble into back of the male or female plug. When you
feel or hear a "click" the pin contact assembly is seated correctly.
Unlock the DC connector
- Use the specified wrench tool.
- When separating the DC + connector, push the tool down from the top.
- When separating the DC - connector, push the tool down from the bottom.
- Separate the connectors by hand.

6.3 AC Connection

Step 1: AC String Connection
HS/AS series inverters are designed for single-phase grid. Voltage range is 220/230/240V; frequency is
50/60Hz. Other technical requests should comply with the requirement of the local public grid.
Table1: Without EPS Function (internal)
HS-3.0
Model
AS-3.0
Cable (GRID)
4.0mm²
Cable (EPS)
4.0mm²
Micro-Breaker
Table2: With EPS Function (internal)
HS-3.0
Model
AS-3.0
Cable (GRID)
8.0-10.0mm²
Cable (EPS)
4.0mm²
Micro-Breaker
50A
Pin contact cable nut
HS-3.7
AS-3.7
4.0mm²
4.0mm²
25A
25A
HS-3.7
AS-3.7
8.0-10.0mm²
4.0mm²
50A
HS-4.6
HS-5.0
AS-4.6
AS-5.0
6.0mm²
6.0mm²
6.0mm²
6.0mm²
32A
HS-4.6
AS-4.6
8.0-10.0mm²
8.0-10.0mm²
6.0mm²
6.0mm²
63A
18
HS-6.0
AS-6.0
6.0mm²
6.0mm²
32A
40A
HS-5.0
HS-6.0
AS-5.0
AS-6.0
8.0-10.0mm²
6.0mm²
63A
63A