INSTALLER MANUAL FORCE SERIES GRID-TIED INVERTERS This guide describes how to use and install Energizer Solar Inverters. To prevent improper operation before use, please carefully read this manual. ________________________________________________________________________________________________________ Energizer Solar Inverter | Installer Manual...
This manual describes the assembly, installation, commissioning, maintenance and troubleshooting of the following model(s) of Energizer Solar Inverters: Energizer Force 3S | Energizer Force 3.6S | Energizer Force 4.6S | Energizer Force 5S | Energizer Force 6S Note! Please keep this manual where it will be accessible at all times.
Prior to touching any part of the inverter please ensure surfaces and equipment are under touch safe temperatures and voltage potentials before proceeding. 2.2 PE Connection and Leakage Current PV System Residual Current Factors ________________________________________________________________________________________________________ Energizer Solar Inverter | Installer Manual...
All Energizer solar inverters incorporate a certified internal RCD (Residual Current Device) to protect against possible electrocution in case of a malfunction of the PV array, cables or inverter (DC). The RCD in Energizer solar inverters can detect leakage on the DC side. There are 2 trip thresholds for the RCD as required by the DIN VDE 0126-1-1 standard.
30 volts. 3. Product information 3.1 About Energizer Solar Inverters This series of Energizer solar inverters cover 3kW systems up to 6kW and are integrated with 2 MPP trackers with high efficiency and reliability. 3.2 Basic Features Advanced DSP control technology.
USB Port (For Upgrade) WiFi/GPRS/LAN (Optional) AC Connector Grounding Screw *DC Switch only available in EU models. Not available in AU/NZ. Note! Only authorized personnel are permitted to set the connection. 3.4 Dimensions ________________________________________________________________________________________________________ Energizer Solar Inverter | Installer Manual...
21.7 26.1 Max. AC Current [A] 14.3 17.2 22.0 23.9 26.1 1 (Adjustable from 0.8 leading to 0.8 lagging) Displacement Power Factor Total Harmonic Distortion (THDi, <3% <3% <3% <3% <3% Nominal output) ________________________________________________________________________________________________________ Energizer Solar Inverter | Installer Manual...
Do not install in places where gas or flammable substances may be present. Avoid electromagnetic interference that can compromise the correct operation of electronic equipment. The slope of the wall should be within ±5°. ________________________________________________________________________________________________________ Energizer Solar Inverter | Installer Manual...
Choose the wall location you want to install the inverter. Place the bracket on the wall and mark the position of the 3 holes from bracket. Drill holes with an electric drill, making sure the holes are at least 50mm deep, and then tighten the expansion tubes. ________________________________________________________________________________________________________ Energizer Solar Inverter | Installer Manual [10]...
Step 1: PV String Connection This series of Energizer solar inverters can be connected with 2-strings of PV modules. Please select suitable PV modules with high reliability and quality. Open circuit voltage of module array connected should be less than 600V, and operating voltage should be within the MPPT voltage range.
Page 13
· When separating the DC + connector, push the tool down from the top. · When separating the DC - connector, push the tool down from the bottom. · Separate the connectors by hand. ________________________________________________________________________________________________________ Energizer Solar Inverter | Installer Manual [12]...
Page 14
• Grid Connection This series of Energizer solar inverters are designed for single-phase grid. Voltage range is 220/230/240V; frequency is 50/60Hz. Other technical requests should comply with the requirement of the local public grid. Model Force 3S Force 3.6S Force 4.6S...
Screw the ground screw with screwdriver as shown below: 5.8 Communication Device Installation (Optional) This series of Energizer solar inverter is available with multiple communication options such as WiFi, LAN, GPRS, RS485, Meter and USB with an external device. Operating information like output voltage, current, frequency, fault information, etc., can be monitored locally or remotely via these interfaces.
Page 16
CT (optional) The Energizer solar inverter has an integrated export management function. To enable this function, a power meter or CT must be installed. The CT should be clamped on the main live line of the grid side. The arrow on the CT should be pointing towards the grid.
Page 17
Short press the touch key to switch display or make the Value+1. Long press the touch key to confirm your setting. • DRM0/ESTOP Model Socket asserted by shorting pins Function DRM0 Operate the disconnection device. ESTOP Emergency stop the inverter. ________________________________________________________________________________________________________ Energizer Solar Inverter | Installer Manual [16]...
Page 18
Unscrew the waterproof lid of the USB port using a flat-headed screwdriver as below. Warning! Make sure the directory structure is strictly in accordance with the above. Do not modify the program file name! It may cause the inverter to cease functioning. ________________________________________________________________________________________________________ Energizer Solar Inverter | Installer Manual [17]...
Page 19
Details of how to enable this mode are contained in the "Advanced Configuration Guide”, which can be accessed at our website at https://www.energizersolar.com • Power Derating for Voltage Variation (Volt-Watt Mode) Details of how to enable this mode are contained in the "Advanced Configuration Guide", which can be accessed at https://www.energizersolar.com ________________________________________________________________________________________________________ Energizer Solar Inverter | Installer Manual [18]...
Please set-up the inverter if it is the first time to start-up. The above steps are for the regular start-up of the inverter. If it is the first time to start up the inverter, you need to carry-out the initial set-up of the inverter. ________________________________________________________________________________________________________ Energizer Solar Inverter | Installer Manual [19]...
The touch key is used to set the LCD to display different parameters. Press time <1s (short press): Next; Touch Key Press time >2s (long press): Enter. Wait time 15s: Return to start. ________________________________________________________________________________________________________ Energizer Solar Inverter | Installer Manual [20]...
6.2 Function Tree ________________________________________________________________________________________________________ Energizer Solar Inverter | Installer Manual [21]...
7. Maintenance This section contains information and procedures for solving possible problems with the Energizer solar inverter and provides troubleshooting tips to identify and solve most problems that could occur. 7.1 Alarm List Fault Code Solution SPS Fault - Turn off the PV and grid, reconnect them.
Page 24
- Check if the environment temperature is over the limit. If any of these faults cannot be resolved by following the guidance provided, please contact the Energizer Solar Inverter Support Team: Call us on +61 1300 757 827. Email us on hello@energizersolar.com.
Are the display panel and the communications cable properly connected and undamaged? For further assistance, please contact the Energizer Solar Inverter Support Team (Call us on +61 1300 757 827. Email us on hello@energizersolar.com) and have relevant information ready including a description of your system installation, the model and serial number, and any issues and troubleshooting you have already attempted.
When the inverter or other related components need to be disposed of, please ensure it is carried out according to local waste handling regulations. Please be sure to deliver any inverter that needs to be disposed from sites that are appropriate for the disposal in accordance with local regulations. ________________________________________________________________________________________________________ Energizer Solar Inverter | Installer Manual [25]...