lost, the inverter export power is limited to the set Soft Limit value.
Hard Limit:
After setting the Hard Limit value, if the Soft Limit time requirement is not met or if the CT or meter
communication is lost, the inverter will disconnect from the grid and shut down.
BMS
Communication interface between inverter and battery is RS485 or CAN with a Rj45 connector.
PIN
1
2
3
4
5
6
7
8
BAT AWAKEN GND_COM
/
BMS_CANL BMS_CANH BMS_CANH BMS_CANL
/
Definition
Connection steps:
Step 1: Prepare a standard network cable and cable connector, then insert the network cable through the
cable connector.
Step 2: Crimp the cable with a Rj45 plug which is inside of the cable connector.
Step 3: Insert the cable connector into BMS port at the bottom of inverter and screw it tightly.
28