Efficiency, Safety And Protection - Energizer Solar Force HS-3.0 User Manual

Table of Contents

Advertisement

4.5 Efficiency, Safety and Protection

Model
EFFICIENCY
MPPT Efficiency
Euro-Efficiency
Max. Efficiency
Max. Battery Charge
Efficiency
(PV to BAT) (@full
load)
Max. Battery
Discharge Efficiency
(BAT to AC) (@full
load)
Standby Consumption
[W]
STANDARD
Safety
EMC
Certification
Protection
Insulation Monitoring
Residual Current
Monitoring
DC Reverse Polarity
Protection
Anti-islanding
Protection
AC Short-Circuit
Protection
AC Overcurrent
/Overvoltage
Protection
DC Switch
Battery Wack-up
Function
Over voltage category
AFCI
HS-3.0
HS-3.7
AS-3.0
AS-3.7
99.90%
99.90%
95.26%
95.70%
97.01%
97.08%
98.50%
98.50%
97.00%
97.00%
G98 / G99 / AS/NZS4777-2:2020 / EN50549-1 / CEI 0-21 / VDE-AR-N 4105 / NRS097-2-1 and so on
HS-4.6
AS-4.6
99.90%
96.23%
97.04%
98.50%
97.00%
<10
EN 62109-1/ EN 62109-2
EN 61000-6-2/ EN 61000-6-3
YES
YES
YES
Active Frequency Drift with Positive Feedback
YES
YES
YES
YES
III(AC), II(DC)
optional
11
HS-5.0
HS-6.0
AS-5.0
AS-6.0
99.90%
99.90%
96.30%
96.33%
97.08%
97.08%
98.50%
98.50%
97.00%
97.00%

Advertisement

Table of Contents
loading

Table of Contents