Electrical Connection; Pv Connection (For Hybrid Only) - Energizer Solar Force HS-3.0 User Manual

Table of Contents

Advertisement

Step 2: Match the inverter with wall bracket
Hang the inverter over the bracket, slightly lower the inverter, and make sure the 2 grooves on the back
are fixed with the 2 mounting bars from bracket properly. Fixing inverter with the supplied M5 screw.

6. Electrical Connection

6.1 PV Connection (For Hybrid Only)

Step 1: PV String Connection
HS series inverters can be connected with 2-strings of PV modules. Please select suitable PV modules
with high reliability and quality. Open circuit voltage of module array connected should be less than 600V,
and operating voltage should be within the MPPT voltage range.
Note!
Please choose a suitable external DC switch if the inverter does not have a built-in DC switch.
Warning!
PV module voltage is very high and within a dangerous voltage range, please comply with the
electric safety rules when connecting.
Warning!
Please do not make PV positive or negative to ground!
Note!
PV modules: Please ensure they are the same type, have the same output and specifications,
are aligned identically, and are tilted to the same angle. In order to save cable and reduce DC
loss, we recommend installing the inverter as near to the PV modules as possible.