Q5X Laser Triangulation Sensor With Dual Mode And IO-Link For Jam Detection Instruction Manual
Features
The Q5X Laser Triangulation Sensor with Dual Mode for Jam Detection has three major features.
Q5X Features
2
1
Display and Indicators
The display is a 4-digit, 7-segment LED. Run mode is the primary view displayed.
For JRET, JBGS, 2-pt, BGS, FGS, and DYN TEACH modes, the display shows the current distance to the target in
centimeters. For Dual TEACH mode, the display shows the percentage matched to the taught reference surface. A display
value of
Display in Run Mode
1
Output Indicator
On—Output is on
Off—Output is off
Stability Indicator (STB)
On—Stable signal within the specified sensing range
Flashing—Marginal signal (low excess gain), the target is
outside the limits of the specified sensing range, or a multiple
peak condition exists
Off—No target detected within the specified sensing range
Buttons
Use the sensor buttons (SELECT)(TEACH), (+)(CH1/CH2), and (-)(MODE) to program the sensor.
July 10, 2023
3
indicates the sensor has not been taught.
2
STB FLO
BGS
Two output indicators (amber)
1.
Display
2.
3.
Buttons
Stability Indicator (STB—Green)
1.
2.
Active TEACH Indicators
◦
FLO—Amber
◦
RET—Amber
◦
BGS—Amber
Active TEACH Indicators (FLO, RET, BGS)
RET on—Jam Retroreflective TEACH mode selected (default)
BGS on—Jam Background Suppression TEACH mode
selected
RET and BGS on—Foreground suppression TEACH mode
selected
BGS and FLO on—Background suppression TEACH mode
selected
FLO and RET on—Dynamic TEACH mode selected
RET, FLO, and BGS all off—Two-point TEACH mode
selected
RET, FLO, and BGS all on—Dual TEACH mode selected
Button Layout
© Banner Engineering Corp.
7