Fayat Group Dynapac CP2100 Instruction Manual page 38

Pneumatic tire roller
Table of Contents

Advertisement

Id
Byte . Bit
1
0.0
2
0.1
3
0.2
4
0.3
5
0.4
6
0.5
7
0.6
8
1.0
9
1.4
10
3.1
11
3.0
12
3.2
13
3.3
14
2.3
15
2.0
16
2.1
17
2.2
18
2.6
19
1.1
20
1.2
21
4.0
22
4.1
23
4.2
32
Instrument/controls - Description and function
Fail list
Description
Hydraulic Filter
No Charging
Low Spr. Water
Engine Temp
Hydraulic Temp (Temperatura hidráulica)
Battery tension will be monitored.
< 9 V ou > 36V = SAFE MODE
< 18V ou > 32V = LIMITED MODE
Sensor tension error. 5V.
<4,875V or >5,125V out of range of work
Error in the hydraulic pump front valve
Error Feedback / Resistance Valve out of range.
Error in reverse of the valve of hydraulic pump
Error Feedback / Resistance Valve out of range.
Error in the Motor Control Valve
Error Feedback / Resistance Valve out of range.
Hydraulic motor valve BPD.
Error Feedback
Error in the rotation of the pump / diesel engine / Input
Frequency >10.000 Hz
Short circuit on FNR
Inch sensor error
Throttle pedal sensor error
Error in rotation motor H1/ Frequency >8.000 Hz
Error in direction motor (sensor x joystick)
Error in J1939
Coolant Level
Oil Pressure
Water in Fuel
LIMITED Mode
Limits the speed to 50%.
This mode is active as long as the fault remains.
SAFE Mode
The machine stops and cannot be used before the fault is
corrected.
4812314580EN
Air Filter
Low Fuel
Action
LED
LED
LED
LED
LED
LED
LED
Safe Mode
Safe Mode
Limited Mode
Limited Mode
Limited Mode
Limited Mode
Limited Mode
Safe Mode
Limited Mode
Limited Mode
Limited Mode
Limited Mode
Limited Mode
LED
LED
LED
2020-01-06

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dynapac cp2100w10000511clc00961910000516vlc009620