Commissioning
4.2

Control cabinet installation

Extreme environmental conditions
Extreme environmental conditions can cause damage to the device.
• Avoid extreme environmental conditions.
• Protect the device against dust, moisture and heat.
Lack of air circulation
Incorrect installation of the device prevents air circulation in the device and thus causes overheating and
impaired functioning.
• Only install the device in the corresponding wall in the orientation shown.
The device is designed for installation in the front of a control cabinet in machine and system engineering.
The environmental conditions specified for operation must be observed.
Dimensions
The dimensions of the panel PC can be found on the Beckhoff website: https://www.beckhoff.com/de-de/
support/downloadfinder/technische-zeichnungen/.
All dimensions are in mm.
Preparation of the control cabinet
The control cabinet must have the required installation cutout according to the device dimensions of the
panel PC.
The wall thickness must be between 1 mm and 5 mm for installation. In the case of a device with a stainless
steel front, the panel thickness must be between 1 mm and 3 mm. After installation, be sure to check the
tightness between the panel PC and the wall.
Please also note the following for installation in a control cabinet:
• Ensure that there is 5 cm of free space above and below the device for air circulation.
• Position the panel PC such that reflections from light sources on the screen are avoided as far as
possible.
• For the correct installation height, use the position of the screen for guidance. This should always be
optimally visible to the user.
• Do not expose the panel PC to direct sunlight.
Installation in the control cabinet
Once you have made the required cutout in the control cabinet, you can install the panel PC in the control
cabinet. Clamping levers are provided at the back of the housing for mounting of the device. In the delivery
state, the clamping levers are turned onto the device (see Fig. 13).