Installation and Operating instructions for
CP22xx
Multi-touch built-in Panel PC
Version: 1.4
Date:
2021-09-30

Advertisement

Table of Contents
loading

Summary of Contents for Beckhoff CP22 Series

  • Page 1 Installation and Operating instructions for CP22xx Multi-touch built-in Panel PC Version: 1.4 Date: 2021-09-30...
  • Page 3: Table Of Contents

    Table of contents Table of contents 1 Foreword Notes on the Documentation 1.1.1 Liability Conditions 1.1.2 Trademarks 1.1.3 Patent Pending 1.1.4 Copyright 1.1.5 State at Delivery 1.1.6 Delivery conditions Description of safety symbols Basic safety measures Operator’s obligation to exercise diligence 1.4.1 National regulations 1.4.2...
  • Page 4 3.2.2 Installation in a control cabinet wall 3.2.3 Mounting of the Panel PC Power Supply of the Industrial PC 3.3.1 Beckhoff power supply technology 3.3.2 Pin assignment of the connector Fitting the power supply cable Connecting Power Supply 3.5.1 Cable Cross Sections 3.5.2...
  • Page 5 Table of contents Beckhoff Support and Service 9.1.1 Beckhoff branches and partner companies 9.1.2 Beckhoff company headquarters Approvals for USA and Canada FCC Approvals for the United States of America FCC Approval for Canada CP22xx...
  • Page 6: Foreword

    Modifications to hardware or software configurations other than those described in the documentation are not permitted, and nullify the liability of Beckhoff Automation GmbH. 1.1.6 Delivery conditions In addition, the general delivery conditions of the company Beckhoff Automation GmbH apply. CP22xx...
  • Page 7: Description Of Safety Symbols

    Foreword 1.2 Description of safety symbols The following safety symbols are used in this operating manual. They are intended to alert the reader to the associated safety instructions. Acute risk of injury! If you do not adhere the safety advise adjoining this symbol, there is immediate danger to life and health of individuals! DANGER Risk of injury!
  • Page 8: Basic Safety Measures

    Foreword 1.3 Basic safety measures Before the Panel PC is switched off, software that is running must be properly closed. Otherwise it is possible that data on the storage medium is lost. Please read the section Switching the Panel PC on and off.
  • Page 9: Operator's Obligation To Exercise Diligence

    • the operation manual is in good condition and complete, and always available for reference at the location of the product. Do not open the housing of the Panel PC! For technical support contact Beckhoff Service. Note 1.4.1 National regulations Depending on the type of machine and plant in which the Panel PC is used, national regulations governing the controllers of such machines will apply, and must be observed by the operator.
  • Page 10: Product Description

    2.1 Product overview The high-performance multi-touch built-in Panel PC The new Beckhoff Panel PC generation with industry-standard multi-touch display offers a feature-laden solution for any application. The wide selection of models offers different display sizes and formats as well as custom designs. Even for single-touch users, this new Panel PC generation offers an excellent price-to-performance ratio and represents an economical alternative to other systems.
  • Page 11: Appropriate Use

    Product Description 2.2 Appropriate Use The multi-touch built-in Panel PC CP22xx is designed for industrial application in machine and plant engineering. A multi-touch display is accommodated in an aluminium housing. The Panel PC is installed in the front of control cabinets. Risk of explosion! The Panel PC must not be used where there is a risk of explosion.
  • Page 12: Interfaces

    Product Description 2.4 Interfaces X102 X103 X104-X107 X108 X109 X110 Ground COM1 DVI out LAN1 LAN2 Power 2.4.1 Serial interface COM1 (X102) The Panel PC has one serial interface COM1 (X102) using the type RS232, which is brought to a 9 pin SUB-D plug connector.
  • Page 13: Access To Memory Devices, Battery And Fan

    Product Description 2.5 Access to memory devices, battery and fan The slots for the memory devices, the battery and the fans are located behind a cover at the top side of the Panel PC. 2.5.1 Removing the Cover For removing the cover unlock the two clips (see arrows). The cover can now be folded out. cover Picture: CP2212, view from the top empty slot (SATA 1)
  • Page 14: Mounting The Cover

    For optimal cooling the CP22xx Industrial PC is equipped with two fan cartridges. The fan cartridges can be exchanged. Exchanging the fan cartridges Replace the fans only with the identical type or an alternative type approved by Beckhoff. Attention fan cartridge (1) screw (2) For exchanging the fan cartridge (1), first unloose the screw (2).
  • Page 15: Extension For Pcie Plug-In Cards

    Option Extension C9900-B517 2 PCIe module slots, integrated in the CP22xx for plugging-in Beckhoff-PCIe modules 2.5.5 Access to the module slots The PCIe module slots are located behind the cover plate next to the interfaces of the Panel PC. cover plate (1) mounting screws (2) For mounting of a plug-in card first unloose the screws (2).
  • Page 16: Installation

    4. Please keep the associated paperwork. It contains important information for handling the unit. 5. Check the contents for visible shipping damage. If you notice any shipping damage or inconsistencies between the contents and your order, you should notify Beckhoff Service. CP22xx...
  • Page 17: Installation In The Control Cabinet

    Installation 3.2 Installation in the control cabinet The Panel PC CP22xx is designed for mounting in control cabinets in machine and plant engineering applications. The ambient conditions specified for operation must be observed (see chapter Technical Data). 3.2.1 Preparation of the control cabinet The control cabinet wall must be prepared with the required mounting opening according to the Panel PC’s dimensions (see chapter Assembly...
  • Page 18: Mounting Of The Panel Pc

    Installation 3.2.3 Mounting of the Panel PC The Panel PC is installed in the cabinet wall with clamping levers. For the cutout dimension of the Panel PC see chapter Technical Data, the wall thickness is between 1 mm and 5 mm. 1.
  • Page 19: Power Supply Of The Industrial Pc

    (UPS) using the battery pack Note C9900-U330. Danger of Explosion! Danger of Explosion if using other battery packs! WARNING 3.3.1 Beckhoff power supply technology Example: Schematic diagram of power supply unit wirings CP22xx...
  • Page 20: Pin Assignment Of The Connector

    The new Beckhoff power supply technology approach addresses this problem and now offers the user the option of switching the PC off without the need for using the battery, thereby reducing the load on the battery.
  • Page 21: Fitting The Power Supply Cable

    Installation 3.4 Fitting the power supply cable Fit the cables for the power supply of the Industrial PC, the connection of the battery pack as well as the connection of the power-switch in accordance with the wiring diagram, using the included material for assembling the connectors: Material for assembling the connectors Plug connector 8-pole, Strain relief housing with lacing cord...
  • Page 22: Connecting Power Supply

    Installation 3.5 Connecting Power Supply The external wiring consists of the connection of the power supply, the battery pack (optional) and the connection of customized components for shutting down the PC. 3.5.1 Cable Cross Sections For the connection of the power supply, wiring with a cable-cross-section of 1.5 mm must be used.
  • Page 23: Ups Output

    Installation 3.5.5 UPS output In order to maintain a screen display for the PC in the event of a power failure, the power supply unit is equipped with a UPS output for connecting a Control Panel. The maximum load for the output is 1.4 A. 3.5.6 UPS output function •...
  • Page 24: Connecting The Panel Pc

    Installation 3.6 Connecting the Panel PC The mains plug must be disconnected Please read the documentation for the external devices prior to connecting them! Attention During thunderstorms, plug connector must neither be inserted nor removed! When disconnecting a plug connector, always handle it at the plug. Do not pull the cable! 3.6.1 Connecting cables The connections are located at the bottom of the Panel PC and are documented in the chapter Interfaces.
  • Page 25: Operating Instructions

    Operating Instructions 4 Operating Instructions 4.1 Switching the Panel PC on and off 4.1.1 Switching on The Panel PC does not have its own mains power switch. As soon as the power supply is switched on the Panel PC is activated. 4.1.2 Shutting down and switching off Control software such as is typically used on Industrial PCs permits various users to be given different rights.
  • Page 26: Servicing And Maintenance

    Operating Instructions 4.3 Servicing and maintenance 4.3.1 Cleaning Disconnect power supply Switch off the device and all connected devices, and disconnect the device from the power supply. DANGER The device can be cleaned with a soft, damp cleaning cloth. Do not use any aggressive cleaning materials, thinners, scouring material or hard objects that could cause scratches.
  • Page 27: Ups Software Components (Optional)

    Industrial PC. On delivery of the Beckhoff Industrial PC with operating system the software is already installed. Should the software not be installed on your PC, the drivers can be installed from the driver CD provided.
  • Page 28: Troubleshooting

    No power supply to the Panel PC Check power supply cable Cable not connected Correctly connect cable Call Beckhoff Service Panel PC boots, software starts, but Cause of the fault is either in the Call the manufacturer of the control does not operate correctly...
  • Page 29: Assembly Dimensions

    7 Assembly dimensions For the assembly dimensions of the Panels PC please visit our homepage. Here you will find the actual drawings using the link: http://www.beckhoff.de/german/download/technical_drawings.htm Notice mounting orientation The assembly of the unit must take place with the orientation diagrammed here.
  • Page 30: Technical Data

    Technical Data 8 Technical Data Risk of explosion! Do not use the Panel PC in areas of explosive hazard! Danger Pixel errors Pixel errors in the TFT display are production-caused and represent no complaint- reason! Note Anomalies of the Touchscreen Anomalies of the touchscreen sensor are production-caused and represent no complaint-reason! Note...
  • Page 31: Appendix

    Please contact your Beckhoff branch office or partner company for local support and service on Beckhoff products! The contact addresses for your country can be found in the list of Beckhoff branches and partner companies: www.beckhoff.com. You will also find further documentation for Beckhoff components there.
  • Page 32 Appendix 9.2 Approvals for USA and Canada 9.3 FCC Approvals for the United States of America FCC: Federal Communications Commission Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.