Clock configuration setup in XMC7000 MCU family
Internal clock configuration
5.9.1.2

Configuration

You can configure these parameters in the Peripheral-Clocks tab of the Device Configurator; based on these,
ModusToolbox™ software automatically generates the corresponding code.
In the Device Configurator, select the System tab.
1.
Select FLL, and in the FLL – Parameters pane, under General, enter the Desired Frequency (MHz) as
2.
to set the frequency as 80 MHz.
80.000
Select CLK_HF0 and select CLK_PATH0 in Source Clock
3.
Select CLK_PERI, under General, enter '1' in Divider
4.
In Peripheral-Clocks tab, set the parameters as follows:
5.
Figure 36
Setting parameters for PCLK configuration