ZETRON 4000 Sereis Manual page 128

Communication control system operation
Table of Contents

Advertisement

Operating IntegratorRD Workstations
submenu or Subscriber List window). From the MAP27 Dispatcher submenu, pressing the
button multiple times displays Priority 0, 1, 2, 3, then "Restore." The Subscriber List
subwindow lists the priority selections 0, 1, 2, 3, and "Restore." Select the desired Priority
level ("Restore" brings the level back to the level programmed in the M827 database),
then press the Set Pri'ty button. The first idle M427 Dispatcher Port is automatically
highlighted, then a message indicating success or failure of the operation displays in the
channel box. The Pri'ty x button displays the current Priority level.
Call Type Filtering
The Call Types allowed by a radio or M427 Dispatcher Port may be changed by the
dispatcher. To view or change the Call types allowed for a console-connected radio or
M427 dispatcher port, highlight the desired MAP27 channel and click Call Types
(available in the "MAP27 Dispatcher" submenu or Subscriber List window). A new sub-
menu/sub window displays showing the current state of the Call filtering for the selected
radio or Dispatcher Port (options are Voice Call, Status Call, SST/MST call, and CallBack
mode). A black button or "1" indicates the option is enabled and a white button or "0"
indicates the option is disabled. Click the buttons or select the options to toggle the state of
any options, then click Perform Update. A message indicating success or failure of the
operation appears in the channel box, and the option buttons reflect the revised status of
Call filtering. See
Figure 51: MAP27 Call Type Filtering Submenu
128
Figure
51.
Note
Some radios do not support this feature. In this case, the message
Not Spprtd is displayed in the channel box.