Mitsubishi MELSEC F FX-40DU-E Handy Manual page 41

Table of Contents

Advertisement

4.
USER SCREEN MODE
Guide
to
Screen Objects
Size
Minimum: 16 dot x 16 dot.
Maximum: 240 dot x 128 dot.
Number of displayed objects
One specified area is counted as one object, regardless of its size.
Maximum number of displayed objects: 32 per screen.
Display example
Use of lamp objects
(1)
Use in conjunction with TEXT.
The area occupied by a text object is specifiedfor highlighting.
[Example]
*
LAMP
*
18 Control device
When ON
. . . . . . . . . . . . . . . .
Text object
r..
. . . . . . . . . . .
AUTOMATIC
+
:
8
-
, -
:
AUTOMATIC
:
OPERATION
L
. . . . . . . . . . . . . >
:
OPERATION
:
1
. . . . . . . . . . . . . . . .
J
(2) Use in conjunction with TEXT and BOX.
The area occupied by a text object is enclosed in a box and specified
for highlighting.
Text object
BOX
*
LAMP
. . . . . . . . . . . . .
MOTOR
L . . . . . . . . . . . . .
RUNNING
+
mi
j
ON
OFF
ON
OFF
T
i
not displayed
d
o i n is
4 -
ASSEMBLY PROCESS MONITOR
TARGET
ACHIEVEMENT
Text
-
Text
i
Box
+
Lamp
( 6 )
LAMP (EXT)
Number
Bar Graph
Number of Objects
Number
Box
2
External outputs 0 0 to 0 7 of the FXDU-E can be switched ON and OFF in accordance with the
ONIOFF status of programmable controller bit devices.
Since the external outputs can be controlled independently, with one point assigned to each, they
can be used as programmable controller outputs. LAMP (EXT) objects are controlled by the
programmable controller and are not displayed on the screen.
Applicable devices
Programmable controller bit devices
...
X, Y, M, S. T. C
Output destinations
External outputs: 0 0 to 0 7
Logic
An external output is switched ON when the corresponding programmable controller bit device
comes ON (in the case of a normally open contact) or when it goes OFF (in the case of a normally
closed contact)
ON
Programmable controller bit device
OFF
ON
External output
Normally open contact
O F F
Normally closed contact
o,<
OFF

Advertisement

Table of Contents
loading

Table of Contents