This manual contains text, diagrams and explanations which will guide the reader in the correct installation
and operation of the FX
attempting to install or use the unit. Further information can be found in the FX
hardware manuals.
Guidelines for the safety of the user and protection of the FX
Expansion Memory
If in doubt at any stage during the installation of the FX
consult a professional electrical engineer who is qualified and trained to the local and national standards.
If in doubt about the operation or use of the FX
nearest Mitsubishi Electric distributor.
Under no circumstances will Mitsubishi Electric be liable or responsible for any consequential damage
that may arise as a result of the installation or use of this equipment.
All examples and diagrams shown in this manual are intended only as an aid to understanding the
text, not to guarantee operation. Mitsubishi Electric will accept no responsibility for actual use of the
product based on these illustrative examples.
Owing to the very great variety in possible application of this equipment, you must satisfy yourself as
to its suitability for your specific application.
Note's on the symbology used in this manual
At various times through out this manual certain symbols will be used to highlight points of information
which are intended to ensure the user's personal safety and protect the integrity of the equipment.
Whenever any of the following symbols are encountered, its associated note must be read and
understood. Each of the symbols used will now be listed with a brief description of its meaning.
Hardware warnings
1) Indicates that the identified danger WILL cause physical and property damage.
2) Indicates that the identified danger could POSSIBLY cause physical and property damage.
Associated Manuals
Manual name
FX
/FX
/FX
1S
1N
2N
¤
Programming Manual II
¡ FX
Hardware Manual
2N
¡ FX
Hardware Manual
2NC
¤: Indispensable manual
¡: Either manual is necessary
1. Product Outline
1.1 Features
FX
-ROM-E1 and FX
2N
external ROM instruction.
In the products, system programs to add external ROM instruction, EXTR (FNC 180), and the EEPROM
memory which can be used as a PLC program area are built in.
1.2 Programming Tools Applicable for EXTR (FNC 180) Instruction
Model name
GX Developer
FX-PCS/WIN-E
FX-10P-E
FX-20P-E (FX-20P-MFXD-E)
FX
/FX
Function Expansion Memory. It should be read and understood before
2N
2NC
Manual number
/FX
JY992D88101
2NC
(sent separately)
JY992D66301
(included with product)
JY992D76401
(included with product)
-ROM-CE1 are optional memories for the FX
2NC
Version
SW7 or later
3.10 or later
4.10 or later
5.10 or later
/FX
FUNCTION EXPANSION MEMORY
2N
2NC
HARDWARE MANUAL
/FX
2N
2NC
/FX
Function Expansion Memory please consult the
2N
2NC
Explains the instructions in the FX
FX
/FX
2N
2NC
Describes the contents related to the hardware
such as specification, wiring and mounting of
the FX
2N
Describes the contents related to the hardware
such as specification, wiring and mounting of
the FX
2NC
JY997D00401A
or FX
2N
/FX
Function
2N
2NC
Function Expansion Memory always
Description
Series PLC.
Series PLC.
Series PLC.
or FX
Series PLC to add
2N
2NC
series PLC
2NC
/FX
/
1S
1N

Advertisement

loading

Summary of Contents for Mitsubishi FX2N-ROM-E1

  • Page 1 • All examples and diagrams shown in this manual are intended only as an aid to understanding the text, not to guarantee operation. Mitsubishi Electric will accept no responsibility for actual use of the product based on these illustrative examples.
  • Page 2: Specifications

    2. Specifications -ROM-E1 function expansion -ROM-CE1 function expansion Model name memory cassette memory board PLC version 3.00 or later PLC version 3.00 or later (Serial number 15**** or later) (Serial number 15**** or later) Applicable PLC If installed in PLC earlier than version 3.00, only 16k-step user program memory and clock function can be used.
  • Page 3: Operation

    When using K10 to K13 of the EXTR (FNC 180) instruction, operation monitoring, control value write or parameter monitoring and change in the A500/E500/S500 (with RS-485 communication function) Series MITSUBISHI TRANSISTORIZED INVERTER can be performed. The details of programming and setting can be found in the Programming Manual II, JY992D88101.
  • Page 4: Pin Number

    • Connecting with two or more inverters (Maximum 8 inverters) 1) PLC 2) Inverter , FX S500 (with RS-485 communication function), (version 3.00 or later) E500, A500 series PU (RS-485) connector Station number 0 Station number 1 Station number 7 Inverter Inverter Inverter...
  • Page 5 • Connecting with two or more inverters (Maximum 8 inverters) 100Ω 1/4W terminal resistor (prepared by the user) attached to the remotest inverter from PLC 110Ω terminal resistor Distribution Distribution Distribution terminal terminal terminal -485ADP FX -485-BD 24V DC LINK 50mA 10 BASE-T 5 4 3 6 1...
  • Page 6 Manual number : JY997D00401 Manual revision : A Date : JULY 2001 HEAD OFFICE : MITSUBISHI DENKI BLDG MARUNOUTI TOKYO 100-8310 TELEX : J24532 CABLE MELCO TOKYO HIMEJI WORKS : 840, CHIYODA CHO, HIMEJI, JAPAN...
  • Page 7 Mitsubishi Electric will accept no responsibility for actual use of the • Don’t attach/remove the memory cassette or memory board before turning off the power.
  • Page 8 Inverter Class D grounding 5 4 3 6 1 Manual revision : A Date : JULY 2001 HEAD OFFICE : MITSUBISHI DENKI BLDG MARUNOUTI TOKYO 100-8310 TELEX : J24532 CABLE MELCO TOKYO HIMEJI WORKS : 840, CHIYODA CHO, HIMEJI, JAPAN...

This manual is also suitable for:

Fx2nc-rom-ce1