8.Troubleshooting
Symptom / Issue
The boxes are not picked or
dropped reliably
Nothing happens when the
vacuum and/ or blowoff is activ-
ated
PowerPick - Instruction Manual
Cause
The vacuum level at the suction cups is
not at the right level.
There must be an electrical or pneumatic
issue
Table 8-1: PowerPick20 Troubleshooting Guidelines
Solution
Validate that the PowerPick20 vacuum generator
input pressure is at the right level.If needed,
increase it to 7 bar (1 00 psi).
Verify that the suction cups are in good condition.If
needed, clean them (please refer to the
Maintenance section).If wear is visible, replace them
(please refer to the Spare Parts, Kitsand Accessories
section).
Verify that there is no air leak in the circuit between
the PowerPick Controller and the suction cups.
Verify that the air path and manifold are clean and
not obstructed.
Make sure the wires are correctly connected (please
refer to the Electrical Installation section).
Verify that the feed air pressure is at least 3 bar (43.5
psi)