11

Maintenance

11.1

Safety notes

Caution
Before any maintenance work takes place, ensure that the power supply has been switched off and the
system is de-energised.
Notice
All maintenance work must be carried out according to the safety regulations.
In order to ensure the maximum availability and lifetime of the system, we recommend you regularly check the filter
system and ventilation and keep the surrounding area clean. Before switching on the system, make a visual inspection
of the lenses.
11.2

Changing of the laser source filter mat

This laser system is equipped with air cooling. A filter mat is used to protect the electronic components from dust and
impurities in the ambient air. This filter mat should be checked and replaced at regular intervals to ensure an optimal
cooling situation.
The filter pad is located behind the ventilation slots on the front of the laser rack or on the Pc.
Filter pad on the laser rack:
1. Cover of the filter pad.
Maintenance