MAINTENANCE

5
MAINTENANCE

5.1 Cleaning the System

Caution – use of controls or adjustments or performance of procedures other
than those specified herein may result in hazardous laser radiation exposure.
Before starting cleaning and maintenance work always switch off the device
and unplug the mains plug.
You should inspect at least once a day whether any dust has collected on the
focusing lens. Should there be any dust, the lens must be cleaned.
Cleaning intervals will greatly depend on the type of material that you are
working with, and on the length of use of the machine. Remember that a
clean, well maintained unit will provide the best performance and will
minimize service costs. If the laser beam passes through an unclean lens,
the lens can be easily damaged since the dust will most often absorb the
CO
laser's beam. A very dirty housing on an air-cooled laser will lead to
2
overheating and thus to the laser's breakdown.
General cleaning:
1. Switch off the machine.
2. Clean the lens on the underside of the scanner.
3. Clean the housing for the laser source.

5.2 Cleaning the Optical Parts

Trotec recommends to use following cleaning material:
Lens tissues
Lens cleaner
The lens is of high quality and will not be damaged when cleaned carefully
and correctly.
Use each cleaning cloth one time only.
Cleaning instructions:
Use oil-free, water-free air pressure in order to remove all particulate from the surface
of the lens.
This guarantees that the lens will not be scratched during the subsequent cleaning with
cleaning cloths and fluid.
14/10/2015
Part number 69249
Part number 69248
Trotec Laser GmbH