5 MAINTENANCE

5.1

Cleaning the System

Caution - use of controls or adjustments or performance of procedures
other than those specified herein may result in hazardous laser
radiation exposure.
Before starting cleaning and maintenance work always switch off the
device and unplug the mains plug.
You should check at least once a day, whether dust has accumulated
in the engraving system. In case of soiling the machine must be
cleaned.
The cleaning interval strongly depends on the material that is being
processed and the operating time of the device. Please bear in mind
that only a clean machine guarantees optimal performance and reduces the service
costs.
CAUTION: Always keep the system clean, as flammable parts in the
working area or exhaust area rise the fire hazard.
General Cleaning:
1.
Move the working table into a position in which it is easiest for you to clean
the surface with a window cleaning agent and paper towels.
2.
Make sure, that the device is switched off and unplugged. Open the
protective cover.
3.
Thoroughly remove all loose dirt particles and deposits in the interior of the
machine.
4.
Clean the cover of the laser tube.
5.
You can clean the acylic cover with a cotton cloth. Do not use paper towels
as they could scratch the acrylic.
8026 | V5.0_EN (11/2015)