Digital input function parameter list

Use Pr.525 to Pr.531 to assign signals to terminal X1 to X7. The settings of Pr.525 to Pr.531 are the same as those of Pr.178
to Pr.189 (Input terminal function selection). For details of Pr.178 to Pr.189, refer to the FR-E800 Instruction Manual
(Function).
Pr.
Name
525
X1 terminal function
T761
selection
526
X2 terminal function
T762
selection
527
X3 terminal function
T763
selection
528
X4 terminal function
T764
selection
529
X5 terminal function
T765
selection
530
X6 terminal function
T766
selection
531
X7 terminal function
T767
selection
*1
Available for the standard model and the Ethernet model.
NOTE
• The signals assigned to terminals X1 to X7 can be input only via physical terminals.
Initial value
9999
9999
9999
0 to 5, 7, 8, 12 to 16, 18, 22, 23, 25
9999
65 to 67, 72, 74, 76, 84
9999
9999
9999
Setting range
*1
, 26, 27, 30, 37, 42, 43, 46, 47, 50 to 52, 54, 62,
*1
, 87 to 89, 92, 9999
CONTROL CIRCUIT INPUT SIGNAL