Adjusting The Maximum Temperature Stop - Triton OMNICARE ULTRA CINCULT09W Manual

Electric shower
Table of Contents

Advertisement

INSTALLATION
ADJUSTING THE MAXIMUM TEMPERATURE TO 41°C
(If not adjusting the maximum temperature then this step can be ignored)
The shower unit is supplied factory set to give a nominal maximum temperature of
43°C, however, the temperature selector mechanism can be adjusted to restrict the
maximum temperature to 41°C. Follow the instruction below to adjust the setting,
ensure that the electricity supply has been isolated before starting.
14-1
Rotate the knob adaptor clockwise until
it hits the stop on the valve mechanism
as shown above.
14-3
Rotate the splined spindle until the inner
arrow aligns with the 41°C mark (for
maximum temperature to be 41°C).
Knob Adaptor
20
14-2
Remove the screw holding the knob
adaptor in place, and remove the
knob adaptor.
14-4
Replace the knob adaptor so it's in the
orientation shown above. Refit the
screw securing the knob adaptor.
Step
Step
14