INSTALLATION
BEAB CARE* MAXIMUM TEMPERATURE
(If not adjusting to BEAB Care then this step can be ignored)
IMPORTANT: This process should only be performed by a qualified engineer
*BEAB care mark specification states a MAXIMUM of 41°C outlet temperature.
If the shower is adjusted above the maximum 41°C the product falls outside the
BEAB care mark specification.
Ensure that the electricity supply has been isolated before starting.
- Rotate the knob adaptor clockwise until it hits the stop on the valve mechanism,
see
14-1
- Remove the Screw holding the knob adaptor in place and remove the knob
adaptor, see
14-2
- Rotate the splined spindle until the inner arrow aligns with the 41°C mark, see
- Connect the 6-way cable from the cover to the socket on the power PCB cable.
Note: The cable connector can be fitted to the socket one way only.
Run the shower for a minimum of 30 seconds to allow the water temperature
from the handset to stabilise.
- Adjust the splined spindle until 41ºC is achieved from the shower - rotate clockwise to
increase the temperature or anti-clockwise to decrease the temperature.
- Isolate the electricity.
- Remove the cover and unplug the 6-way cable from cover to the power PCB.
- Replace the knob adaptor so it's in the orientation shown in
securing the knob adaptor.
After the cover has been permanently fitted, perform the maintenance
checks detailed on page 28.
- Temporarily fit the cover to the shower, minor
adjustment of the temperature dial may be
necessary to align with the valve. Secure the cover
in position with one of the retaining screws
- Restore the electricity supply to the shower.
- Check the water temperature is within the range
of 5 -20°C.
- Check the terminal voltage at the appliance is
within 230V +/-10%.
- Start the shower by pressing the start/stop
button.
- Measure the outlet water temperature at the
shower head.
21
14-3
.
and refit the screw
14-4
Step
Step