Drain Pump Connectivity - Triton OMNICARE ULTRA CINCULT09W Manual

Electric shower
Table of Contents

Advertisement

INSTALLATION

DRAIN PUMP CONNECTIVITY

(If no drain pump is being connected to the shower then this step can be ignored)
This Omnicare product has been designed to operate with analogue drain pumps
only.
Configuration 1 for Analogue Drain Pumps
When the shower is turned on, a signal is sent to the drain pump electronics telling
the pump to start. When the shower is turned off, a signal is sent again to the drain
pump electronics telling the pump to stop; generally after a preset time delay. This
type of pump makes no allowance for the flow rate of the water from the shower, the
'gulp' or speed of the pump is fixed.
DIP switch 4 On
Analogue Pump Setting
The pump manufacture provides a two core cable for connection to the shower
unit.
Connect the drain pump Control Wire as below:
1 - Not Used (connections numbered from left)
2 - Any
3 - Any
Note: Please reference the relevant pump manufacturers installation
instructions for pump connection and relevant IEE regulations.
3
2
1
17
Step
Step
9
Drain Pump Connection
Terminal Block