TEMPERATURE ADJUSTMENT
Important
The mixer shower has a temperature stop
to prevent accidental rotation to higher
temperatures. This is adjustable to provide a
maximum temperature of 35°C – 46°C.
The mixed water temperature can be adjusted
from cold through to a top limit (which can
be pre-set during installation – factory set
at approximately 38°C) with full anti-scald
protection throughout the range.
Should there be a loss of flow to either incoming
supply then water from the mixer shower will
stop or be reduced until both supplies are
restored.
Recommended Outlet Temperatures
The BuildCert TMV scheme recommends a
maximum mixed water outlet temperatures of
41°C for showers.
The mixed water temperatures must never
exceed 46°C.
The British Burns Association recommends 37°C
to 37.5°C as a comfortable bathing temperature
for children.
WARNINGS
Exposed metal surfaces may become hot during
use.
Push button mixer shower
Adjusting the Maximum Temperature
Override Setting
Remove the temperature control by removing
the end cap and unscrewing the retaining screw
(fig.23).
Turn the flow control to full flow. With a
steady flow running, adjust the temperature
valve spindle until the temperature is about
38°C.
When you are satisfied with the temperature
turn the flow control off. Refit the temperature
control. Secure with the screw and replace the
end cap.
15
Fig.23

Advertisement