Bosch AUTODOME 7100i Installation Manual page 54

Hide thumbs Also See for AUTODOME 7100i:
Table of Contents

Advertisement

54
en | Connection
Figure 10.4: Connections with the power supply with wall arm
1
2
3
4
2023-09-29 | V06 | F.01U.410.315
Ground screw
P101 Connector; Power In (120 VAC /
230 VAC, 50/60 Hz)
Ground wire connects to external Earth
Ground
Power In; 3/4 in. (20mm) NPS Fitting to
electrically grounded metal conduit
Note: The cable should remain on the
high voltage side of the metal divide
that separates high voltage from low
voltage in the power supply.
6
7
8
9
Installation Manual
AUTODOME 7100i│AUTODOME 7100i IR
Ground wire to wall arm mount
P107 Connector; 24 VAC (pins 4, 5) and
ground (pin 3) to camera through the
wall arm mount
Note: Must use P107 pins 4, 5 for
24VAC power since that uses the 3.15 A
fuse in the power supply.
P107 Connector; 24 VAC (pins 4, 5) and
ground (pin 3) to camera through the
wall arm mount
Note: Must use P107 pins 4, 5 for
24VAC power since that uses the 3.15 A
fuse in the power supply.
(Optional pass-through) Audio input+/-,
Audio Output+/-, Alarm IN 1, Alarm IN
2, Relay NO, Relay NC, Relay COM,
DGND to a low voltage; 1/2 in. (15 mm)
NPS Fitting from the camera, through
the arm mount to electrically grounded
metal conduit.
Note: Audio and alarm I/Os pass
through the Power supply box.
Bosch Security Systems

Advertisement

Table of Contents
loading

Table of Contents