Making Connections In The 24Vac Power Supply With Lid (Nda-U-Psu0, Nda-U-Psu1, Nda-U-Psu2) - Bosch AUTODOME 7100i Installation Manual

Hide thumbs Also See for AUTODOME 7100i:
Table of Contents

Advertisement

60
en | Connection
10.3.7
Making connections in the 24VAC power supply with lid (NDA-U-PSU0,
NDA-U-PSU1, NDA-U-PSU2) - (for non-IR NDP-7602-Z40 camera models)
Bosch recommends operating the AUTODOME 7100i IR camera models (NDP-7602-Z40L,
NDP-7604-Z12L) by IEEE 802.3bt PoE, Type 4, 90W. You can also use a third-party 24 VAC,
50/60Hz power supply that meets the stated requirements.
Refer to the subchapter Recommendations for 24 VAC Power Supply for details.
Danger!
The NDA-U-PA0, NDA-U-PA1, and NDA-U-PA2 surveillance cabinet PSUs by Bosch are not
compatible with the AUTODOME 7100i.
Warning!
Because the IR models of the AUTODOME 7100i (NDP-7602-Z40L, NDP-7602-Z12L) are
rated to 24VAC @ 3.5A, which will exceed the current output of the 3.15A fuse (labeled
!
XF103 in the power supply), you cannot use the IR models of the AUTODOME 7100i camera
with the following power supplies:
VG4-A-PSU0, VG4-A-PSU1, VG4-A-PSU2, NDA-U-PSU0, NDA-U-PSU1, NDA-U-PSU2
Danger!
For the 120VAC and 230VAC models of the 24VAC VG4 power supply (VG4-A-PSU1 and VG4-
A-PSU2) and for the 120VAC and 230VAC models of the 24VAC power supply (NDA-U-PSU1
and NDA-U-PSU2), route only the 120VAC and 230VAC cables and Earth ground in the high
voltage section of the power supply. Do not route any other wires through the high voltage
section of the power supply.
Warning!
All wiring (power and I/O cabling) connecting to the unit must be routed separately inside
!
permanently earthed metal conduits (not supplied).
2023-09-29 | V06 | F.01U.410.315
Installation Manual
AUTODOME 7100i│AUTODOME 7100i IR
Bosch Security Systems

Advertisement

Table of Contents
loading