8.
9.
10. Make sure the installation is liquid tight.
Note: The length of wires that are exposed outside the grounded metal conduit and outside
the NDA-U-RMT should be kept as short as possible.
Warning!
DO NOT RELY ON THE GROUND WIRE TO SUPPORT THE WEIGHT OF THE GROUNDED
!
CONDUIT.
The grounded conduit must be adequately supported by separate mounting hardware and
not by the grounding wire.
9.2

Recommended routing of Ethernet cable through Pipe Mount

1
Bosch Security Systems
Unscrew the bolt at the bottom of the NDA-U-RMT and add the 3/8" (9.5 mm) washer
and the 3/8" (9.5 mm) ring terminal on the ground wire.
Make sure there is a low resistance measurement between the metal of the bolt head
and the grounded metal conduit so that the electrical ground is connected between the
NDA-U-RMT and the grounded metal conduit.
1 Bottom view of the pipe mount
2
2 Top view of the pipe mount
Installation Manual
Installing a pipe mount | en
2023-09-29 | V06 | F.01U.410.315