Making Connections In The Power Supply With Wall Arm (Nda-7100-Pa0(F), Nda-7100-Pa1(F) - Bosch AUTODOME 7100i Installation Manual

Hide thumbs Also See for AUTODOME 7100i:
Table of Contents

Advertisement

AUTODOME 7100i│AUTODOME 7100i IR
10.3.5
Making connections in the power supply with wall arm (NDA-7100-
PA0(F), NDA-7100-PA1(F), NDA-7100-PA2(F))
Warning!
If you reuse a VG4-A-PSU0, VG4-A-PSU1 and VG4-A-PSU2 (from an earlier Bosch AUTODOME
!
camera) to provide power to an AUTODOME 7100i/AUTODOME 7100i IR camera:
a) You must redo the cable wiring as illustrated.
b) Do not connect any wires to connectors P106 and P105 of the PSU.
Warning!
Because the IR models of the AUTODOME 7100i (NDP-7602-Z40L, NDP-7602-Z12L) are
rated to 24VAC @ 3.5A, which will exceed the current output of the 3.15A fuse (labeled
!
XF103 in the power supply), you cannot use the IR models of the AUTODOME 7100i camera
with the following power supplies:
VG4-A-PSU0, VG4-A-PSU1, VG4-A-PSU2, NDA-U-PSU0, NDA-U-PSU1, NDA-U-PSU2
Warning!
All wiring (power and I/O cabling) connecting to the unit must be routed separately inside
!
permanently earthed metal conduits (not supplied).
Danger!
For the power supply models with 120VAC or 230VAC transformers (VG4-A-PSU1, VG4-A-
PSU2, NDA-U-PSU1 and NDA-U-PSU2): Route only 120VAC / 230VAC wiring and Earth
ground through the conduit holes in the high-voltage section of the power supply. Do not
route any other wires through the high-voltage section of the power supply.
Figure 10.3: 24VAC power supply with (1) the high-voltage section (120VAC, 230VAC), (2) the low-
voltage section (24VAC), and (3) the metal barrier that separates the two sections
Bosch Security Systems
Installation Manual
Connection | en
2023-09-29 | V06 | F.01U.410.315