52
A00VF2C526DA
4139fs2538c0
[3]
A00VF2C581DA
Field Service Ver. 1.0 Aug. 2006
12. Hold onto the handle, pull it and
remove the toner cartridge [1].
13. Repeat steps 11 and 12 to remove
all toner cartridges.
14. Remove the drum cartridge.
See P.17
NOTE
• Position the removed drum car-
tridge as shown in the illustration at
the left.
• Be sure to keep the drum cartridge
horizontal and place it where it will
not become dirty.
• Do not leave the drum cartridge
removed for more than 15 minutes,
and do not place the removed drum
cartridge in a location where it will
be exposed to direct light (such as
sunlight).
15. Remove the PH unit cover/right [1],
left [2].
CAUTION
• Through the hole [3] at the location
shown on the left, push the tab of
the PH unit cover and remove the
PH unit cover.
• Note the connector connected to
the PH unit cover/right. Use care
not to pull the unit with an exces-
sive force, so you don't break the
wire.