Detection Area - Optex REDSCAN mini-Pro Series Settings Manual

Laser scan detector
Hide thumbs Also See for REDSCAN mini-Pro Series:
Table of Contents

Advertisement

RLS-2020V 1.x.x (xxxx/xx/xx)
Saved.
Apply settings
Press 'Apply settings' after all settings
are finished.
Detection range
This will restart or reboot the detector.
Detection range
Detection profile 1
Detection profile 2
Detection mode
Event code
View
Tilt direction
Date and Time
Network
Maintenance
Information
RLS-2020V 1.x.x (xxxx/xx/xx)
Apply settings
Detection range
Detection profile 1

Detection area

Area Masking/Allocating
Detection
Detection advanced
Output terminal
Detection profile copy
Detection profile 2
Event code
View
Date and Time
Network
Confirm
Outdoor
OK
Auto
Detection range expansion
High resolution
Area set
Save
Detection area
Detection range A (m)
20
Height or Depth (m)
20
Offset (mm)
500
Edit area
?
Save
Confirmation 3
Final confirmation of the detection range settings,
after saving them.
4-2. Detection profile 1
?
4-2-1. Detection area
Detection range A
Height or Depth
Offset
(mm)             [ 0 to 1,000 (= 1 m) ]
Edit area
Open the separate window to edit the detection area.
Detection Range
Detection area can be limited by "range A", "range B" and
"Height or Depth". Yellow line will indicate the effective
detection range after settings are completed.
Offset
Perimeter of detection area near background can be
excluded by the Offset distance. In vertical mode,
obstacles on the ground or floor can generate false alarm.
Also, plants and small animals can cause false alarm.
18
Normal
Expansion
(m) [ 0 to 20 ]
[ 0 to 30 ]
(m)     [ 0 to 20 ]
[ 0 to 30 ]
4. Settings

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rls-2020vRls-2020a

Table of Contents