RLS-2020V 1.x.x (xxxx/xx/xx)
Apply settings
Detection range
Detection profile 1
Detection area
Area Masking/Allocating

Detection

Detection advanced
Output terminal
Detection profile copy
Detection profile 2
Event code
View
Date and Time
Network
Maintenance
Information
Display
Display the sensing area.
Update the sensing area.
Save
Detection
Use multi detection sensitivity
Detection target
Mobile object
Moving distance (mm)
1000
Sensitivity (msec)
1000
Throw-in detection
Minimum target size
300
(width)(mm)
Ignoring Area from
250
Ground (mm)
Minimum tracking size (mm)
Maximum tracking size (m)
Display
Display sensing area.
Update the sensing area
4-2-3. Detection
Multi settings
If "Use multi detection sensitivity" is selected, each
detection area can be configured independently.
Detection
?
Use multi detection sensitivity
A11
A12
Detection target
Moving distance (mm)
Detection target
Moving distance (mm)
[ 500 to 10,000
The Moving distance is to avoid false alarm caused by static
obstacles. If an object is detected longer than the moving
distance, alarm is rised.
Sensitivity (msec.)
[ 50 to 900,000
The Sensitivity is to avoid false alarm caused by instantaneous
event. If an object is detected longer than the Sensitivity time,
alarm is raised.
Throw-in detection
50
Detects objects that pass quickly through the detection area,
such as thrown objects. Since it detects instantly, the risk of
2.5
false alarm increases depending on the environment.
Minimum target size (width) (mm)
[ 10 to 1,000
The Size is to avoid false alarm caused by small object. If an
object is smaller than Minimum Target Size, the object is
ignored.
Ignoring Area from Ground (mm)
[ 1 to 5,000
Objects near to ground are ignored. Enter the height of the
ignoring area.
Minimum tracking size (mm)
If an object is smaller than Minimum Tracking Size, the object
is ignored. After an object is detected, the object is tracked
while the size is larger than Minimum Tracking Size.
Maximum tracking size (m)
If an object is bigger than Maximum Tracking Size, the object
is ignored. After an object is detected, the object is tracked
while the size is smaller than Maximum Tracking Size.
22
B11
B12
A21
Mobile object
[ Mobile object, Presence ]
Mobile object
(= 0.5 to 10 m)
]
Presence
(= 15 min.)
]
(Ver.2.1 or later)
*2.1
(= 1 m)
]
Vertical mode
(= 5 m)
]
[ 10 to 1,000
[ 1 to 50 ]
4. Settings
A22
B21
1000
only
only
Presence
only
only
(= 1 m)
]